Files
archie/internal/logging/feed_test.go
T
sam a27d430215 feat(logging,workflow): daemon log feed and executable workflow registry
Add internal/logging.Feed, a logging-owned bounded replay buffer separate
from the persisted task-lifecycle event stream, with a live SSE endpoint.
Expose the executable workflow registry (skillbuild.Catalog) including
zero-run definitions and their origin (builtin vs. installed skill), not
just historical run statistics. Route() now returns an explicit failure
workflow for an unknown pre-assigned workflow name instead of silently
falling through to label-based routing.

Fixes #54
2026-08-09 01:26:10 +10:00

35 lines
956 B
Go

package logging
import (
"context"
"log/slog"
"testing"
)
func TestFeedCapturesStructuredSlogEntriesInOrder(t *testing.T) {
feed := NewFeed(2)
logger := slog.New(NewFeedHandler(slog.NewJSONHandler(testWriter{}, nil), feed))
logger.Info("started", "component", "daemon")
logger.Warn("slow", "component", "worker")
entries := feed.Snapshot()
if len(entries) != 2 || entries[0].ID == 0 || entries[1].ID <= entries[0].ID {
t.Fatalf("entries = %#v", entries)
}
if entries[0].Message != "started" || entries[0].Fields["component"] != "daemon" {
t.Fatalf("first entry = %#v", entries[0])
}
ctx, cancel := context.WithCancel(t.Context())
defer cancel()
updates := feed.Subscribe(ctx)
logger.Error("failed", "component", "worker")
if got := <-updates; got.Message != "failed" || got.Level != "ERROR" {
t.Fatalf("live entry = %#v", got)
}
}
type testWriter struct{}
func (testWriter) Write(p []byte) (int, error) { return len(p), nil }