Files
archie/internal
sam a6ac25876a fix(webui): the wildcard listen address is not loopback
IsLoopback(":8484") returned true: the empty host fell through the
switch as loopback, so a wildcard bind skipped the non-loopback token
requirement and served every interface unauthenticated. An empty host is
the wildcard, not loopback.