docs/prds/runtime-control-plane.md ("API") requires a live change to start
and check the new component before switching to it, keeping the old one
running when the check fails. The live workflow-execution-settings apply
stored whatever arrived on the watch, republished the configuration snapshot
new tasks are built from, and reported success unconditionally.
Stage the update as a candidate first: validate the limits and build the
snapshot they produce without touching anything running, then switch both in
only if the check passes. A refused update leaves the running limits and the
snapshot in place and reports the failure through the apply-status surface,
which keeps the version that is still live and carries the error. Boot
propagates the same rejection, so a process is never started on limits it
cannot run.
personas is the other live-watched kind and gets no check or report here;
filed as archie-core-nw7t rather than half-wired.
Closes archie-core-nwa0.