sam 0b1a852650 fix(messaging): gate the boundary on config reads, not only package links
The deletion gate checked which packages the messaging binary links, so a
process that reads a decoded [models]/[providers] value passed while
building an LLM client in-process. Go imports are atomic, but a config
read leaves no import to measure.

- add the model-provider capability packages (transcription, embedding)
  to the banned-link table and classify links through a testable
  bannedLink rule.
- scan internal/app/archiemessaging's production sources for a read of a
  top-level config section the PRD forbids, so the projection that built
  the transcriber cannot come back.
- unit-test both rules, including a synthetic copy of the old wiring, so
  the live gate cannot rot into a no-op and still pass.

Red first: TestMessagingReadsNoBannedConfigSection failed on cfg.Models
and cfg.Providers before the capability moved, and the link gate failed on
internal/infrastructure/transcription.
2026-10-02 11:12:59 +10:00
..