The daemon can now re-read its configuration on SIGHUP (or on a
future in-process trigger) and republish it through the Holder,
closing the first half of issue #348: 'config can change at runtime,
safely, and can't brick the daemon.'
Reload path:
- cmd/archied/reload.go: ReloadController re-runs loader.Resolve on
the same paths main.go passed at startup (Resolve is pure -- no
reload state added to the loader). apply is called only with a
Document that passed validation; a failed reload records the error
and its timestamp and leaves the running config untouched. That
Set-not-called-on-error property is the safety core and is pinned
by TestReloadValidationFailureDoesNotApply.
- SIGHUP listener in main.go runs reloadLoop(ctx, ch, controller, log);
the loop is extracted as a testable seam (syscall.SIGHUP is Unix-only,
fine given the Linux target).
PollInterval is genuinely reloadable now, not just re-read:
the three ticker sites (Run, per-identity goroutine, shared
maintenance loop) re-read the interval each tick and Reset the ticker
on change. A reloaded poll_interval takes effect on the next cycle.
Diff-and-warn so an operator never has to read the source to know
whether an edit took effect: changedNonReloadableFields compares the
old and new snapshots against an allowlist of re-read fields
(PollInterval, Repos, DiffCapLines, Budgets, Dispatch, and the
Containers sub-fields VolumeTTL + MaxConcurrency). Anything else that
changed logs Warn 'requires a restart'; a fully-applied reload logs
Info. The allowlist is deliberate: a field added to Config later
defaults to requires-restart, the safe direction.
NATS split-brain closed: containerEnv now hands containers the
endpoint the daemon's own client connected with at startup
(Daemon.ConnectedNATS, captured at construction) instead of the live
config, so a reloaded nats.url cannot point new containers at a
server the daemon is not publishing on. A nats change is therefore
classified requires-restart, and CLAUDE.md's 'hands its own nats.url
verbatim' note is updated to the meaning it now has (same today,
deliberately different after a reload).
Validation guard: poll_interval <= 0 is rejected in validate.go
beside the VolumeTTL guard. applyDefaults fills zero with 60s, so
this fires on an explicit negative -- which would panic
time.NewTicker/Reset at boot and, after the per-iteration reset,
on a SIGHUP mid-run.
Observability: config.ReloadStatus (last_error, last_error_at,
last_reload_at) is recorded by the controller and surfaced in
/api/config via Server.LastReload, so a stale running config is
visible in the dashboard, not just the logs. Rendering waits for the
UI step.
Recovery hatch: --no-config-overlay flag plus ARCHIE_SKIP_CONFIG_OVERLAY=1
(configuration.SkipOverlay), logged at startup. No overlay source
exists yet; the flag is the documented escape hatch the DB overlay
(step 3 of #348) will consult.
webui.Server.ConfigProvenance becomes atomic.Pointer so a reload can
swap it via SetProvenance independently of Cfg; the accepted skew
(new config alongside old provenance) is documented on the field.
Verified: task check clean; -race on daemon, webui, cmd/archied,
config, infrastructure/configuration.